– 8
Danger
Scalding danger! The operating pressure
must not exceed 3,2 MPa (32 bar) when
operating with temperatures above 98 °C.
Therefore the following measures must
definitely be performed:
Î Replace high pressure nozzle (stain-
less steel) with steam nozzle (brass,
order see specification).
Î Open up the pressure/ quantity regula-
tor on the hand spray gun completely,
direction + until stop.
Î Set the operating pressure on the pump
unit to the minimum value.
Î Set temperature regulator to min. 100 °C.
Î Set dosing value for detergent to "0".
Î Set the appliance switch to "1" (opera-
tion with cold water).
Î Open the hand spray gun and rinse the
appliance for at least 1 minute.
Danger
Danger of scalding by hot water. After the
operation with hot water or steam, the de-
vice must be operated with openend gun
with cold water for at least two minutes.
Î Shut off water supply.
Î Turn on pump shortly (appr. 5 seconds)
by activating the hand spray gun.
Î Set the appliance switch to "0/OFF“.
Î Pull main plug out of socket with dry
hands only.
Î Remove water connection.
Î Activate hand spray gun until device is
pressure less.
Î Lock the trigger gun.
Î Lock in the steel pipe into the holder of
the appliance hood.
Î Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Device with hose drum:
Î Before rolling up, stretch out the high
pressure hose.
Î Turn the hand crank clockwise (Direc-
tion of the arrow).
Note: Do not twist high pressure hose and
electrical conduit.
Caution
Frost will destroy the not completely water
drained device.
Î Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
Caution
Threat of damage by penetrating cold air
through the chimney.
Î Disconnect device from chimney when
outside temperature drops below 0 °C.
If it is not possible to store frost free, shut
down device.
For longer work breaks or if a frost free stor-
age is not possible:
Î Drain water.
Î Flush device with anti-freeze agent.
Î Empty detergent tank.
Î Screw off water supply hose and high
pressure hose.
Î Screw off supply hose at boiler bottom
and drain heating spiral empty.
Î Operate device for max. 2 minutesuntil
the pump and lines are empty.
Operating with steam
After operation with detergent
Turn off the appliance.
Storing the Appliance
Frost protection
Shutdown
Dump water